Platz | Konfig. | Anschlüsse | Erster Kanal | Anschlussdurchmesser | Länge Des Anschlusslanges | Paket | Anschlusstyp |
D1 = 100G | M=Mux | 0102=1Com, 2Out | C61 = 1528, 77nm | 09 = 0, 9mm | 05 = 50cm | A6 | FU(A)=FC/UPC(APC) |
D2 = 200G | D=Demux | 0204=2Com, 4out |
|
20 = 2mm | 10 = 100cm | B1 (2, 3, 4) | SU(A)=SC/UPC(APC) |
/ | MD=M& D |
|
L01 = 1577, 03nm | 30 = 3mm |
|
C1 (2, 3, 4) |
|
|
|
0249=2Com, 40out |
|
|
20 = 200cm | D (1, 2, 3, 4) | LU(A)=LC/UPC(APC) |
Edelstahlrohr (A) | Kunststoffbox (B) | Kasten aus Aluminiumlegierung (C) | Gestell aus Aluminiumlegierung (D) | |||||||||||||||
Übersicht | Übersicht | Übersicht | Montage | Übersicht | Montage | Übersicht | ||||||||||||
/ | / | / | / | / | 44.5x13x2Φ3 | D1 = 129 x 29 x 160 (LGX) | ||||||||||||
|
|
B2 = 100 x 80 x 10 | 70x73.5x4Φ3.2 | C2 = 90x72x8 | 86x68x4Φ3 | D2 = 129 x 58 x 160 (LGX) | ||||||||||||
|
|
B3 = 120 x 80 x 18 | 80x74.5x4Φ3.2 | C3 = 110 x 95 x 7, 5 | 99x84x4Φ3.5 | D3 = 485x43.5x230 (19'-Rack) | ||||||||||||
|
|
B4 = 141 x 115 x 18 | 100x106x4Φ3.2 | C4 = 110 x 95 x 15 | 99x84x4Φ3.5 | D4 = 485x87x230 (19'-Rack) | ||||||||||||
Element | M/D | M& D | ||||||||||||||||
X (DWDM-Kanal) | 2 | 4 | 8 | 16 | 20 | 32 | 40 | 2 | 4 | 8 | 16 | 20 | 32 | 40 | ||||
φ0.9(φ2, φ3) Kunststoffbox | B2 | B2 | B2 | B3 | B3 | B4 | B4 | B2 | B2 | B3 | B4 | B4 | / | / | ||||
φ0.9 (φ2/φ3) Aluminiumlegierungsgehäuse | C2 | C2 | C3 | C4 | C4 | C4 | C4 | C2 | C3 | C4 | C4 | C4 | / | / | ||||
LGX | D1 | D1 | D1 | D2 | 4U | 4U | / | D1 | D2 | D2 | 4U | / | / | / | ||||
19 Zoll Rack | D3 | D3 | D3 | D3 | D3 | D3 | D4 | D3 | D3 | D3 | D4 | D4 | D4 | D4 | ||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Parameter | Einheit | Wert | |||||||||||
Kanalplatz | / | 100G | 200G | ||||||||||
Kanal | Nm | 2 | 4 | 8 | 16 | 32 | 40 | 2 | 4 | 8 | 16 | 20 | |
Passband |
|
|
|
||||||||||
Passband@0.5dB | Nm | > 0, 3 | > 0, 6 | ||||||||||
Passband-Flatness | DB | < 0, 5 | |||||||||||
Einfügungsdämpfung | DB | < 1, 8 | < 2, 0 | < 3, 2 | < 4, 5 | < 5, 5 | < 6, 0 | < 1, 8 | < 2, 0 | < 3, 2 | < 4, 5 | < 5, 0 | |
Isolation (Angrenzend) |
|
> 25 | |||||||||||
Isolation (Nicht Angrenzend) | DB | > 45 | |||||||||||
PDL | DB | < 0, 1 | < 0, 15 | < 0, 2 | < 0, 25 | < 0, 3 | < 0, 1 | < 0, 15 | < 0, 2 | < 0, 25 | |||
PMD | ps/√km | < 0, 1 | < 0, 15 | < 0, 1 | < 0, 15 | ||||||||
Temperaturempfindlichkeit Der Einfügungsdämpfung | DB/ºC | < 0, 002 | Anschlussdurchmesser | Mm | 0, 25 /0, 9 /2 /3 | ||||||||
Wellenlängentemperaturumschaltung | Nm/ºC | < 0, 001 | Länge Des Anschlusslanges | Cm | > 50 | ||||||||
Rückflussdämpfung | DB | > 45 | Tem-Betrieb. | ºC | -5~ +70 | ||||||||
Richtwirkung | DB | > 50 | Speicher-Tem. | ºC | -40~ +85 | ||||||||
Glasfasertyp | / | SMF-28e | / |
|
|
||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|