Input & Output | Analog input | 2 channel,voltage / current signal can be switched,voltage 0~10V,current 0~20mA | ||||||
Digital input | 5 channels / optocoupler isolation, including 1 channel of high-speed pulse input, and the maximum input pulse | |||||||
frequency can reach 100kHz | ||||||||
Analog output | 2 channel, voltage 0~10V,current 0~20mA,Output type switchable | |||||||
Digital output | 2 channel, Optocoupler isolation / open collector output / rated current 20mA (DO,DHO) | |||||||
Digital pulse output | 2 channels / optocoupler isolation / open collector pulse (frequency or PWM) output (O, DHO), including 1 high-speed | |||||||
pulse output, and the maximum output pulse frequency can reach 100kHz | ||||||||
Relay output | 2 channel,Normally open and normally closed contact, 250VAC-3A | |||||||
Communication mode | Standard MODBUS-485 communication protocol | |||||||
Control characteristics | control mode | V / F control: no PG vector control (SVC); with PG vector control (SVC) | ||||||
Frequency setting mode | Keyboard setting, analog setting, pulse setting, communication setting and others | |||||||
Frequency control range | 0.01~500Hz | |||||||
Frequency control accuracy | Digital setting: 0.01Hz; Analog setting: maximum frequency x0.025% | |||||||
Speed regulation ratio | 1:200 ( SVC ) ; 1:1000(FVC) | |||||||
Steady speed accuracy | ±0.5% ( SVC ) ; ±0.02% ( FVC ) ; | |||||||
Acceleration and deceleration time | 1.0 ~ 3600.0s (acceleration and deceleration time can be set separately and S characteristic can be switched) | |||||||
Inching control | Inching frequency range: 0.00hz ~ 100Hz; Jog acceleration and deceleration time: 0.0s ~ 3600.0s | |||||||
Starting torque | 0.5Hz 150% (SVC) is adjustable, and the capacity of frequency converter shall be considered; 3.0Hz 100%(V/F) | |||||||
Torque boost | Automatic torque lifting; Manual torque increase 0.1% ~ 30.0% adjustable | |||||||
Braking torque | Braking resistance braking (125%), DC braking (20%) | |||||||
DC braking | Braking time: 0.0s ~ 36.0s; Braking current: 0.0% ~ 100.0% | |||||||
Timing control | Timing range: 0.0min ~ 6500min | |||||||
PID control | With built-in PID function, it is convenient to realize process closed-loop control | |||||||
V / F curve | Linear, multi-point user-defined curve, 1.1 ~ 2.0 arbitrary power-down curve | |||||||
Multistage speed control | Built in simple PLC can control the maximum 16 speed frequency logic | |||||||
Carrier adjustable | 1.0~16kHz ,adjusted according to the module temperature | |||||||
Frequency setting signal | -10 ~ + 10, 0 ~ + 10, 4 ~ 20mA, high frequency pulse, PWM pulse | |||||||
Protection function | Overload capacity | G:60s-rated current x 150%; 3s-rated current x 200%; P:60s-rated current x 120%; 1s-rated current x 150% | ||||||
Instantaneous overcurrent / short circuit protection | More than 200% of the rated output current, automatically cut off the output | |||||||
Overvoltage / undervoltage protection | When the bus DC voltage is too low (360V) or too high (800V), the motor stops freely (except braking) | |||||||
Open phase protection | In case of phase loss at the input or output end, the motor stops freely | |||||||
Overheat protection | When the radiator temperature is ≥ 85 ºC , the motor will stop automatically; The temperature protection threshold | |||||||
can be set freely according to the ambient temperature | ||||||||
Motor protection | Analog input can be connected with temperature sensor input (PT100, PT1000) to realize motor overheating protection | |||||||
Stall protection | Prevent stall during acceleration or deceleration or operation (working current can be set) | |||||||
Grounding protection | by current sensor | |||||||
Instant stop | The load feedback energy compensates for the voltage reduction and maintains the continuous operation of the frequency | |||||||
converter in a short time | ||||||||
Specification structure | Rated input | voltage : 1/3PH220V±20%; 3PH380V±20% | ||||||
Frequency : 50Hz/60Hz±5% | ||||||||
Cooling and protection | ≤ 18.5kW:IP20; >18.5kW:IP10; forced cooling | |||||||
Use environment | -10 ºC ~+40 ºC ; Altitude: not higher than 1000m; Indoor, no corrosive gas | |||||||
Preservation environment | -20 ºC ~+65 ºC; Humidity: 20-90% RH (no condensation); shock <6m/s2(0.6g) |