The AC70 series general-purpose inverter adopts an open-loop vector algorithm and modular design to realize high-performance and high-precision motor drive control. The product also has an independent air duct, which can effectively prevent dust from entering the circuit board. At the same time, the thickened three anti-paint protection makes it more environmentally adaptable.
Applications:Fans and pumps, air compressors, wire drawing machines, injection molding machines, ball mills, machine tools, industrial washing machines, lifting industries, and other industries and equipment.
Technical
Specification |
Items | Description |
Power range | Single-phase 220V, Three-phase 220V | 0.4kW~220kW |
Three-phase 380V | 0.75kW~710kW | |
Three-phase 660V | 7.5kW~710kW | |
Three-phase 1140V | 37kW~710kW | |
Power Input |
Voltage, frequency | single phase 220V, 3 phase, 220V, 380V, 660V and 1140V |
Allowable fluctions |
Voltage: ±15%; frequency±5%
Distortion of voltage to confirm to IEC61800-2 |
|
Closing striking current | Less than rated current | |
Power Factor | =0.94( integrated DC reactor) | |
Efficiency | =96% | |
Power Output | Output Voltage |
3 Phase, 0~Input voltage, tolerance less than 5% in standard
rating condition |
Frequency control range |
G type: 0 to 400Hz, P type: 0-400Hz, Z type: 0-400Hz, L type:
0-400Hz, H type: 0-3000Hz. |
|
Output frequency accuracy | ±5% of maximum frequency | |
Overload tolerance |
Z type: 150% rated current for 60 sec, 180% rated current for 30
sec, 250% rated current for instantaneous G, H, L type model: 150% of rated output current for 60 sec,180% of rated current for 10s, 2 00% of rated current for instantaneous P type: 120% rated current 60 sec, 150% rated current for instantaneous |
|
Key Control Performance |
Motor control mode | Open loop sensorless vector control without PG, V/F control |
Control system | Optimized Space Vector PWM Modulation | |
Carrier frequency | 0.6~ 15kHz, Randomly-modulated carrier | |
Speed control range | OLV without PG with rated load: 1:100, | |
Stable speed control accuracy | OLV without PG: less than 1% rated synchronous speed | |
Torque response | OLV without PG control mode: =20ms | |
Frequency accuracy |
Digital inputs: maximum × ±0.01%
Analog inputs: maximum × ± 0.2% |
|
Frequency setting resolution |
Digital inputs: 0.01 Hz
Analog inputs: 0.5% of maximum output frequency |
|
Standard Function | DC Baking |
Starting Frequency: 0.00 to 50.00Hz,
Braking Time: 0.0 to 60.0s Braking current: 0.0 to 150% rated current |
Torque boost |
Auto torque boost:0.0% to 100%
Manual torque boost: 0.0% to 25% |
|
V/F curve |
5 kinds curve programmable setting:1 user setting, 1 of linear
characteristic torque curve setting. 3 kinds derating torque setting( 1.5 power, 1.7 power, 2.0 Power curve ) |
|
ACC/DEC curve |
Two kinds curve: line Accel/Decel, S curve Accel/Decel.
4 Aceel/Decel time unit is 0.1s, maximum time 6500.0s |
|
Rated output voltage | Power voltage compensation is available, setting range from 50 to 100%( rated voltage), the output voltage can not over than input | |
AVR(auto voltage regulation) | Automatic voltage regulation for keeping output voltage stable when fluctuation of grid | |
Auto energy saving running | Optimized the output voltage according the load to achieve energy saving | |
Auto current limit | Auto current limit during running mode to avoid trip occurs frequently | |
Momentary Power Loss with
no stop running function |
To achieve continuous running with regenerative enery and DC bus
voltage regulation when momentary power loss |
|
Standard function |
PID control, Carrier frequency adjustable, current limiter, Speed
Search, Momentary Power Loss restart,8 Step Speed (max), 3-wire Sequence, Slip Compensation, Frequency Jump, Upper/lower Limits for Frequency Reference, DC Injection Braking at Start and Stop, Energy Saving Control, Modbus Comm RS485, Fault Restart, job function, Cooling Fan on/off Switch, timing stop, high pulse output, programmable auto running, swing frequency, counter, frequency arriving detect and frequency lever detect. |
|
Frequency Setting Methods |
Keypad digital setting, potentiometer of keypad, analog voltage
terminal VS1, analog voltage terminal VS2, analog current terminal AS, RS485 communication and multiple terminal, main and auxiliary composition setting. |
|
Feedback Input Channel |
Voltage terminal VS1, VS2, current terminal AS, communication ,
and pulse input PUL |
|
Running command channel | Keypad given, external terminal given, communication given | |
Input command signal |
Start, Stop, FEW/Reverse, Job, Multiple speed, free stop, Reset,
Accel/Decel time, Frequency set point channel, External fault |
|
Output signal |
2 Photo coupler relays: 2 (24 V, up to 50 mA)
1 Contact relays: 1 (250 Vac/up to 1 A, 30 Vdc/up to 1 A) 0-10V output, 4 to 20mA output Frequency pulse output |
|
Protection function |
Overvoltage, under voltage, current limit, over current, overload,
electric thermal relay, overheat, Stall prevention, parameter lock |
|
Keypad Display | LED Display |
One line digit-segments LED display to monitor 1 running status;
Double line digit-segment display to monitor 1 running status. |
Parameters copy | Upload and download parameter code to achieve easy copy | |
Monitor Function |
Output frequency, Frequency set point, Out current, Output voltage,
motor speed, PID feedback value, PID given setting, IGBT module temperature, I/O terminal status. |
|
Alarms |
Overvoltage, under voltage, over current, short circuit, phase loss,
over load, over heat, stall prevention, current limit, parameter lock damage, running status at present alarm, past trip alarm |
|
Environment | Installation site |
Indoor, Altitude should less than 1000m, Free corrosive gases and
direct sunlight |
Running Temperature,
humidity |
-10~+40°C ( wall mounting),
20% to 95% RH (No condensation) |
|
Vibration | Less than 0.5g when frequency less than 20Hz | |
Storage Temperature | -25-+65°C | |
Installation mode | Wall-mounted mode, floor stand cabinet install | |
Protection Degree | IP20 | |
Cooling Method |